![]() Does this fit into a standard “group size” battery box? The lowest safe storage temperature is -22☏, so any temperatures below this, you should bring them inside or add a heating pad of some sort, but keep in mind if a heating pad runs out of power and the battery falls below -22☏, damage may occur. What temperatures do the batteries need to be brought out of the cold? If you need to charge the battery in sub-zero temperatures, we recommend adding a heating pad that can be turned on to warm up the battery prior to charging. Yes! The battery will prevent charging below 0☌ in order to protect the cells while continuing to allow discharging. Does this battery have Low-Temperature protection? You may arrange your own HAZMAT shipping from our warehouse, FOB Origin. ![]() We have currently suspended complete shipping to Hawaii & Alaska. IMPORTANT: For battery type, select “USER” Low Temperature Cutoff: Disabled (unless you add a temp sensor, the BMS has this protection built in) Settings for Renogy Charge Controller (Wanderer, etc.) Max Charge Current: OK to set as high as desired, but no more than 50a per batteryĪbsorption Time: 15 Minutes (This allows for proper cell balancing)Įqualize Current: 0% (For safety we don’t want equalization at all.)Įqualize Stop Mode: Automatic (On voltage) ![]() If you want to be more conservative on your time remaining, then set this to 20% Settings for Victron SmartSolar MPPT Charge Controllers:īattery Voltage: Set depending on system, normally 12v. If you choose to fully discharge your battery (not recommended) then set this to 0%. Let’s say you setting this at 10% when you get to 10%, the Smartshunt will indicate 10% remaining and 0 minutes until empty. State of Charge: 30% (NOTE: Set this to 30% with brand new, untouched batteries. Victron Settings For SmartShunt & BMV-712 / SOK Batteryīattery Capacity: Varies depending on system.Ĭharged Voltage: 13.8 (*2 for 24v & *4 for 48v Systems)īattery Starts Synchronized: Disabled (NOTE: you will need to fully charge your battery to sync up SOC%) With this set at 14.6, if an equalization is somehow triggered, you will not damage your battery. If you can, we recommend setting the equalization voltage to 14.6v. Multiply voltages by 2 for 24v systems and by 4 for 48v systems.Ĭharge Current (Per battery): 40a Preferred (50a Maximum)Ībsorption Voltage: 14.6v preferred (14.4 Minimum)įloat Voltage: 13.8v preferred (13.6 Minimum) For Victron BlueSmart Chargers, please refer to the BlueSmart product listing page for exact parameters. General settings that apply to most equipment. Overall Dimensions Including Handles & Terminals (LxWxH) SOK Battery 12V LiFePO4 Spec Sheet: Electrical Properties This means less downtime and lower repair costs to the end-customer, as well as a decreased environmental impact. Each component inside the battery's casing can be easily replaced by either an authorized service agent or the end customer, offering a convenient solution for those who prioritize battery maintenance and reliability. Instead of becoming expensive and toxic waste, the SOK Battery SK48V100 is engineered so that every single part within the battery pack can be field serviced using just a Phillips screwdriver and a 10mm wrench. SOK Battery believes that their batteries are an investment and should withstand the test of time. This is where SOK has distinguished themselves as the leading battery manufacturer. Any attempt to service would certainly void your warranty and the likelihood of a successful service is slim to none. When parts within these permanently assembled packs fail, the entire module is rendered useless and needs to be disposed of as E-waste and replaced as a complete unit. These processes are great for single-use disposable products, but a poor choice for systems expected to last decades. Other batteries on the market prevent user-serviceability and are permanently sealed using techniques such as IR-Laser Welding of aluminum cell-interconnection busbars, plastic injection-molded cases, and permanent epoxy potting during assembly. Failures can also be caused by shipping damage, installer error, downstream equipment malfunction, natural aging, and unavoidable environmental factors such as lightning.Ĭompeting 48V server rack battery manufacturers are not designing their products to handle a failure taking place. All products have an estimated useful life, the amount of time that a product is expected to stay in working order, which can vary slightly depending on the usage, environment, and build quality.
0 Comments
Leave a Reply. |